UPS

Online UPS 10kVA~200kVA EA8900
Series (3:3)
Three phases in, three phases out.
True on-line dual conversion design.
SPWM .
IGBT inverter design.
UPS can carry 100% non-balance load .
Extendable run time .
Generator compatible.
Cold start .
Load/battery capacity display .
Overload, on-line, battery status LED/LCD
display .
Advanced Battery Management .
RS-232 .
Optional SNMP card .

Model

EA8910

EA8915

EA8920

EA8930

EA8940

EA8950

EA8960

EA8980

Rating

10KVA

15KVA

20KVA

30KVA

40KVA

50KVA

60KVA

80KVA

Operating Mode and Principle

True on-Line, Static Bypass (Uninterruptible Switch), Dual Conversion, Output Galvanic Isolation

AC Input

Phase

3 Phases + N + G

Voltage

380V +/- 25%

Frequency

50/60Hz +/- 5%

P.F.

0.92

Soft Stat

0~100% 5s

Bypass Input

Phase

3 phases + N + G

Voltage

380V +/- 25%

Frequency

50/60Hz +/- 5%

Transfer Time

0ms,Inverter/Bypass (Overload)

DC System

Volage

360V (Rated Voltage)

Volage

405V (Float Charge Voltage)

Volage

315V (Shutdown Voltage)

Current

25

38

51

76

101

126

152

203

Current

1A ~ 30A (Adjustable, Charge Current)

AC Output

Phase

3Phases + N + G

Voltage

380V +/- 1%(Stable Load); 380V +/- 5%(Fluctuated Load)

Fequency

50~60Hz +/- 0.05% ( Battery Mode)

P.F.

0.8

Wave

True Sine Wave

Distortion

Total Harmonic Distortion: <3%(Linear Load); <5%(Non-Linear Load)

Time

Transient Recovery Time:<10 ms

Overload

125% for 10 Minutes; 150% for 1Minute

Cooling

Forced Wind

System

Efficiency

91%

91%

92%

92%

932%

93%

93%

95%

Interface

RS232, SNMP

Temperature

0~ 40 C (Operating)

Humidity

30~90%

Optional

Isolation Transformer

Harmonic Suppression Filter

Up to six Parallel Modules

Noise(db)

48-55

53-65

55-65

Dimension(mm)

650x700x1350

760x720x1450

760x850x1500

1100x860x1680


Model

EA89100

EA89120

EA89140

EA89160

EA89200

EA89300

EA89400

Rating

100KVA

120KVA

140KVA

16.0KVA

200KVA

300KVA

400KVA

Operating Mode and Principle

True on-Line, Static Bypass(Uninterruptible Switch), Dual Conversion, Output Galvanic Isolation

AC Input

Phase

3 Phases + N + G

Voltage

380V +/- 25%

Frequency

50/60Hz +/- 5%

P.F.

0.92

Soft Stat

0~100% 5s

Bypass Input

Phase

3 phases + N + G

Voltage

380V +/- 25%

Frequency

50/60Hz +/- 5%

Transfer Time

0ms,Inverter/Bypass (Overload)

DC System

Volage

360V (Rated Voltage)

405V (Float Charge Voltage)

315V (Shutdown Voltage)

Current

253

305

355

405

550

760

1015

Current

1A ~ 30A (Adjustable, Charge Current)

AC Output

Phase

3Phases + N + G

Voltage

380V +/- 1%(Stable Load); 380V +/- 5%(Fluctuated Load)

Fequency

50~60Hz +/- 0.05% ( Battery Mode)

P.F.

0.8

Wave

True Sine Wave

Distortion

Total Harmonic Distortion: <3%(Linear Load); <5%(Non-Linear Load)

Time

Transient Recovery Time:<10 ms

Overload

125% for 10 Minutes; 150% for 1Minute

Cooling

125% for 10 Minutes; 150% for 1Minute

System

Efficiency

95%

95%

95%

95%

95%

95%

95%

Interface

RS232, SNMP

Temperature

0~ 40 C (Operating)

Humidity

30~90%

Optional

Isolation Transformer

Harmonic Suppression Filter

Up to six Parallel Modules

Noise(db)

55-65

60-65

65-70

Dimension(mm)

1100x860x1680

1500x1250x1800

1800x1250x1800

 

EA8900
© Copyrights 2006 CBC INTERNATIONAL LIMITED All Rights Reserved


Specifications