F1500-G series (0.4~160kw)
PRODUCT NEWS

Main Function
--- Special built-in PI adjuster for closed-loop control.
--- Controlled by keypad, 485 communication control box, PC and PLC, and 125 pieces of inverters can be operated at the same time.

--- Line type, square curve type and user-defined type of torque-compensation available, adapted to many kinds of loading mode.
--- Jogging speed control, external analog signal speed control, Multistage speed-control and code timing speed control, PC or PLC speed control.

--- current and voltage stalling adjustment provided
--- Standard Two-line type and three-line type of terminal control
for more flexible manipulation.
--- User-defined analog input voltage signal and current signal all
available, compound speed control and channel switch between
single and double realizable.

--- With the twinkling display of preset frequency, running
frequency can be easily set before running, especially on the
stage of analog speed control.

Item

Contents

Input

Rated Voltage

thee-phase 380V +-15% single-phase 220V +-15%(thee-phase 220V +-15%)

Rated Frequency

50 / 60 Hz(+-5%)

Output

Rated Voltage

3-phase 0 ~ 380V; 3-phase 0 ~ 220 V

Frequency Range

0.00 ~ 400.0 Hz (frequency resolution ratio 0.01Hz)

Overload Capacity

150% 60S

 

Control
Mode

Frequency Setting Accuracy

Digit Setting: 0.01Hz Analog Quantity Setting: Max Frequency x 0.4%

Setting Mode

optimized space vector control

V/F Curve

3 V/F curves. To select and set beeline V/F curve, polygonal line V/F curve and squre V/F curve as per load

Torque Promotion

Manual setting torque promotion within 1 ~ 15%

Automatic Voltage Setting

Automatic setting output voltage to meet input power fluctuation within certain range

Braking Mode

DC Braking+Optimized Energy Braking

PI Adjusting

With built-in PI adjuster for automatic control

Jogging

Jogging Range: 0.00 ~400.0Hz

Automatic Circular Running

User will program output frequency mode as per process requirements

Operation Functions

Frequency Setting

Digit frequency setting, keypad "UP/DOWN" keys setting, "UP" and "DOWN" terminals setting;
Keypad potentiometer or external analog signal (0-10V, 0-20mA) setting;
Analog channel compound operation setting;
Multi-state speed-control and code timing;
485 communication control box / computer setting.

Start/Stop Control

Control over keypad /485 communication control box, terminals and computer

Protection Functions

Input out-phase, input undervoltage, over-voltage, over-current, inverter overload, motor overload, overheat, current check trouble, peripheral equipment trouble, user password error/exterior interference, contactor monitoring.

Display

LED nixie tube showing present output frequency, present rotate-speed, present output current, present output voltage, final axis linear-velocity, exterior pulse count-value, types of failure, function-code parameters and operation parameters;
4 LED indicators showing the current working status of inverter.

Environment Conditions

Environment Location

Free of corrosive gas and dust

Environment Temperature

-10ºC ~ +50ºC

Environment Humidity

< 90 % (no water-bead coagulation)

Vibration Strength

Below <0.5 g (acceleration)

Applicable Motor P

0.4 ~ 160KW

Performance Indexes